Break up of Unit Price of SPIS
SL. No. Name of the Item Qty Unit Rate (Rs.) Qty per SPIS
1 5 Hp or higher Power AC surface water pump 1 46901.00 1
2 Solar PV modules 1 Watt 67.46 5000 Watt
3 Solar VFD controller 1 Set 65722.00 1 Set
4 HDPE Pipe ( Delivery and Suction Side) 50 feet 3087.50 50 feet
5 PVC NRV Foot valve 1 no 2014.00 1 no
6 1 no PVC NRV 3923.50 1 no
7 160 mm dia PVC pipe (2.5 kgf/cm2) 1 mts 322.05 500 mts
8 QRC Outlets 5 Nos 2375.00 5 Nos
9 Tool kit (as per Annexure-3) 1 set 9500.00 1 set
10 Others service charges
SL. No. Name of the Item Qty Specification
1 5 Hp or higher Power AC surface water pump 1 ISI mark 5 Hp AC Surface Solar Water Pumping System (380-415V 3 phase, 50Hz.) delivering water @1, 90,000 litres in 7 hours (per day) at 20 meter height (head). Make-Shakti Brand Pump
2 Solar PV modules 1 Watt MNRE APROVED PV modules – Poly Crystalline solar PV Modules - 5000W including protective enclosure (iron wire fencing) Make- Sova Solar Limited or, Jackson
3 Solar VFD controller 1 Set Solar VFD Controller AC/DC Changeover suitable to run from grid 440 V three phase with wall mounted pre wired (IP55) Steel enclosure with Earthing System ( for enclosure and PV panels) Having following Features: a) Run-stop-restart mode during the day, capable of detecting dysfunctions of the system and has self protection features against over-load, under-load and dry run of pump. b) Harvest maximum solar energy to run the pump for maximum duration in a day by controlling the speed of the motor based on the power availability from solar panel. c) Inbuilt short circuit/Open circuit Reverse Polarity protection d) Having remote monitoring system (RMS) so that pumps installations can be remotely monitored, with data pack for 5 years and full access to data and the server by JSPS. Data stored (water discharge) should be verifiable in RMS within six months of system installation. e) Having facility to run from grid supply during rainy season and/or non sunny days f) HFV having change over switch and programme option for operating two types of motors. g) DC cables from PV panels to Pre-Wired Enclosure- PVC sheathed non-armored flexible 2 core 10 Sqmm multi - strand copper wire / 1000 Volts h) AC cables from Drive to Pump- PVC sheathed nonarmored flexible 4 core 6 Sq mm multi - strand copper wire as per IS 8130 / 1000 volts
4 HDPE Pipe ( Delivery and Suction Side) 50 feet 80/110 mm flexible (ISI Mark)
5 PVC NRV Foot valve 1 no PVC foot valve with clamps and fittings (ISI Mark)
6 PVC NRV 1 no PVC NRV with clamps and fittings (ISI Mark)
7 160 mm dia PVC pipe (2.5 kgf/cm2) 500 mts pressure rating 2.5 Kgf / Sq Cm (ISI Mark)
8 QRC Outlets 5 Nos QRC outlets including clamps and other accessories (ISI Mark)
*All specifications and make of goods indicated by your firm in your bid have to be complied.